Log in  \/ 
x
x
Register  \/ 
x

enid
Milestone ETHOS X for GC and HPLC Analysis Samples submitted for GC and HPLC analysis require pre-treatment. The fundamental step in sample pre.. Product #: ETHOS X for GC and HPLC Analysis In Stock

ETHOS X for GC and HPLC Analysis

Brand: Milestone
Product Code: ETHOS X for GC and HPLC Analysis
Availability: In Stock
Weight: 0.00kg

Several configurations
to accomplish a wide range of applications

The use of microwave energy to accelerate solvent extraction procedures was first described by Ganzler et al. in 1984. These researchers used polar, microwave absorbing solvents or mixtures to extract crude fat from food and pesticides from soil matrices. Microwave extraction rates were found to be significantly faster, with recoveries comparable or superior to traditional Soxhlet extraction, and with a substantial reduction of the amount of solvent required.
New Milestone ETHOS X is an advanced microwave extraction system offering the best technology currently available for GC or GC-MS and HPLC analysis.
  •  Reliable GC or GC-MS analysis
  •  High sample throughput
  •  Low running costs
  •  Efficiency and consistency
  •  Simplicity


 
THE NEW MILESTONE ETHOS X

  • FAST
Microwave extraction is completed in just few minutes. The Milestone ETHOS X can simultaneously process multiple samples in a matter of minutes. Microwave assisted extraction uses closed vessels to heat the extraction solvent above its atmospheric boiling point. The elevated temperature increases the solubility of the analytes of interest and lowers the viscosity of the solvent, allowing it to better penetrate the matrix. This reduced extraction times.
  •  EASY
An important feature of the ETHOS X system is that it easily adapts to existing extraction chemistry. This is accomplished through the use of a unique, patented material, called Weflon. Without Weflon, extractions could only be performed with polar solvents (Acetone, Methanol, etc.) or mixtures of polar and non-polar solvents, because non-polar solvents are not heated by microwaves. Weflon eliminates this problem by acting as a coupling agent. Weflon stir bars are heated by microwaves and they subsequently transfer this heat to the non-polar solvent.
  •  EFFECTIVE AND CONSISTENT
Microwave extraction produces equal or higher analyte recoveries than older methods. Thanks to a combination of higher extraction temperatures, closed vessels, magnetic stirring, and precisely controllable temperature conditions, users of microwave extraction can expect a better quality of the results. The homogeneity of the microwave field and the precision of the temperature control are key elements in microwave extraction.
  •  ECONOMICAL
Lower solvent usage reduces the costs of solvent purchase and disposal. Microwave extractions are carried out in closed, sealed vessels. The matrix is constantly bathed with hot solvent in a self-promoting reflux action with no loss of volatile analytes or solvent. The use of closed vessels, with the speed and efficiency of microwave heating, allows extractions to be performed with significantly less solvent, without sacrificing accuracy or precision. The simplicity of the microwave technique reduces the attended labor time and increases overall productivity.


Higher microwave power for faster vessel heating


  • LARGEST
    MICROWAVE CAVITY
The ETHOS X microwave cavity has a volume in excess of 70 liters, by far the largest currently available. Why is this important? Firstly, extraction rotors with more sample positions can be accommodated, improving productivity. Secondly, the microwave unit is inherently much safer, because a larger cavity better contains gases escaping from vessels, should there be a sudden over pressurization.

  • HIGHEST
    MICROWAVE POWER
Equipped with two 950 Watt magnetrons for a total of 1900 Watt, ETHOS X is the most powerful microwave extraction system available in the market today. The system additionally employs a rotating diffuser that evenly distributes the microwaves throughout the cavity. High power coupled with the diffuser enables very fast heating of high throughput rotors.

  • PRESSURE-RESPONSIVE DOOR
The ETHOS X's stainless steel door features an innovative opening and self-resealing mechanism. In case of a sudden over-pressurization of the cavity, the door slightly opens for rapid pressure release and the microwave power is instantaneously cut off. Immediately afterward, the door is pulled back, resealing the cavity. An automatic door locking system does not allow the user to open the ETHOS X door during the run.

  • TEMPERATURE AND PRESSURE SENSORS
The most advanced yet easy to use reaction sensors are installed for complete quality control of the extraction conditions. Direct temperature and pressure control are used in a single reference vessel. In all vessels, contact-less temperature is used combined with a contact-less pressure sensor that monitors and controls all vessels simultaneously, preventing any leakage or venting.

EasyCONTROL Operating Software

The ETHOS X is controlled via a compact terminal with an easy-to-read, bright, full-color, touchscreen display. The terminal is provided with multiple USB and Ethernet ports for interfacing the instrument to external devices and to the local laboratory network. The terminal runs a completely new user-friendly, icondriven, multi-language software to provide easy control of the microwave run. Simply recall a previously stored method or create a new one, press ‘START’ and the system will automatically follow the user defined temperature utilising a sophisticated PID algorithm. Several applications, including all US EPA and ASTM methods available, are preloaded in the ETHOS X terminal. There is no need to input the number of samples or weights being extracted, as the software will automatically regulate the microwave power accordingly. This assures a consistent quality of extraction and simplifies the use of the instrument.

Temperature control with easyTEMP

The easyTEMP contactless sensor directly controls the temperature of all samples and solutions, providing accurate temperature feedback to ensure complete extraction in all vessels with superior safety. This technology combines the fast and accurate reading of an in-situ temperature sensor with the flexibility of an infrared sensor. The ETHOS X software provides digestion history traceability and temperature measurement for every sample. Temperature diagrams and profiles are displayed in real-time, and can be saved on the ETHOS X terminal.


Expanding the ETHOS capabilities

Flexibility and performance that make the difference

 

The ETHOS embraces Milestone’s philosophy of a “microwave labstation”. The ETHOS platform is capable of several extraction applications: extraction of pollutants from environmental samples can be done in just few minutes, consuming less solvent than other technologies, thereby improving productivity while decreasing costs, all in full accordance with the US EPA 3546. Additional accessories are available to further expand the ETHOS capabilities: a dedicated configuration for total fat determination in food samples which greatly improves turn-around-time, specific rotors to match the requirements of several extraction processes for GC and HPLC analyis, and an easy to use filtration system that improves the workflow and the productivity.
 
SR-15
FOR SOLVENT EXTRACTION
The SR-15 is a very versatile tool to perform solvent extraction. Its wide working range makes it a perfect solutions even for the extraction that requires extreme conditions.
It is composed by 15 high-purity PTFE-TFM vessel with a volume of 100 mL.
  •  UNMATCHABLE VERSATILITY
  •  LARGE SAMPLE MASS
  • HIGH PERFORMANCE

RAR

FOR SOLVENT EVAPORATION

The RAR rotor has been specifically developed to speed up the solvent evaporation process. It's unique design uses disposable aluminium caps, eliminating the cleaning step. The combination of the unique Weflon material nd microwave heating reduce the evaporation to in just few minutes.
  • DIGEST CAPS
  •  FAST SOLVENT EVAPORATION
  •  SAFE
 
SFS-24

FOR SIMULTANEOUS FILTRATION

The Milestone Simultaneous Filtration System (SFS) is a compact and complete workstation to filter up to 24 samples simultaneously in a few minutes. Samples are filtered into standard evaporation tubes, using the Milestone disposable funnels, providing easier handling.
  •  SIMULTANEOUS FILTRATION
  •  UP TO 24 SAMPLES IN FEW MINUTES